Tender For corrigendum : repair/replacement of joinery and roof treatment wk at gym rd and church rd in the area of age b/r-i including repair/replacement of old unsv led fitting internal wiring, db, mcb & misc e/m work at ichhamati line, mynamati line and adjoining area under ge (central) delhi cantt-10
Tender For corrigendum : repair/replacement of existing hard standing work in md accn area of icchamanti lines including repair/ replacement of old unsv led fitting / internal wiring, db, mccb, & misc e/m works at dk-i and adjoint area under ge (central) delhi cantt-10
Tender For supply of acoustic isolation on walls perimeter walls,acoustic isolation partition internal divide between booth and control room,acoustic door voice booth entrance,acoustic door seals acoustic accessories,fabric wrapped acoustic wall panels,provide and install acoustic foam treatment,corner bass traps,carpet tile flooring,wall dampness repair,sealed windows should be provided,target db after installation of services,ac duct wind provision, electrical and civil provisions to be executed as per the standard,amps provision to be provided as per the standard specifications,ceiling illumination light provisions to be made as per the standard specification
Tender For supply of cm of 1.5tr non inverter split ac units , replacement of blower fan motor in 1.5 or 2 tr ac unit , replacement of blower drum in 1.5 or 2 tr ac unit , replacement of condenser fan motor in 1.5 or 2 tr ac unit , replacement of condenser fan blade in 1.5 or 2 tr ac unit , pcb repair for indoor unit of 1.5 or 2 tr ac unit , pcb repair for outdoor unit of 1.5 or 2 tr ac unit , replacement of 1.5 tr rotary compressor in 1.5 tr ac unit , replacement of 1.5 tr rotary compressor in 2.0 tr ac unit , replacement of 25 or 35 mfdcapacitor in 1.5 or 2 tr ac unit , replacement of 2 pole 25 amp contactor for 1.5 or 2 tr ac unit , replacement of 4 or 6 way terminal box for 1.5 or 2 tr ac unit , water service for 1.5 or 2 tr ac unit , blower service for 1.5 or 2 tr ac unit , charging or topping up r22 or r134 gas in existing 1.5 or 2 tr ac unit , replacement of 50mm thick synthetic air filter for 1.5 or 2 tr ac unit , sitc of auto sequential micro controller for 2 no split or window ac units , replacement of faulty 25 a sp mcb in existing db for 1.5 or 2 tr ac unit , site visit for ac fuult clearing with minor repair
Tender For supply of shavo norgren make filter regulator+ lubricator sm60j-2a-m6d-rgl-db , shavo norgren make sn-3604-01 repair kit , shavo norgren make sn-3603-01- repair kit